The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle. Variax clavicle locking plate system stryker meded. Analysis of contoured anatomic plate fixation versus. The acumed clavicle plating system provides surgeons with the ability to. Acumed clavicle plating system acusinch repair system the acumed clavicle plating system is designed to treat simple and complex fractures, malunions, and nonunions. Comments about the acumed locking anterior clavicle plates. The acusinch repair system is used in conjunction with an acumed midshaft or distal clavicle plate to aid in the healing of clavicle fractures. Three patients in the plateout group sustained a further fracture of their clavicle after plate removal. Clavicle plating system acusinch repair system surgical. Occasionally, the inferior portion of the plate needs to be bent slightly anteriorly to conform to the interior angle of the scapula. Lcp superior clavicle plate with lateral extension lcp superior clavicle plate. Mechanical failure of plate breakage after open reduction and. Acumeds anterior clavicle plates are colorcoded gold for quick distinguishing in the or.
With this in mind, stryker has developed the variax clavicle locking plate system. Locking clavicle plating system cambridge orthopaedics. Acumed locking clavicle plating system the acumed locking clavicle plating system is designed to treat simple and complex fractures, malunions, and nonunions. Distal clavicle plate to aid in the repair of clavicle fractures. The clavicle plating system offers low and narrowprofile plate solutions that are precontoured to match the natural shape of the clavicle. Acumed clavicle plating system contains 33 plate designs. Cleared indications for the clavicle plating system. Clavicle plate 19 acusinch repair system surgical technique 25 ordering information 33 clavicle plating diagrams 39 acumed is a global leader of innovative orthopaedic and medical solutions. Is removal of clavicle plate after fracture union necessary. Fixation of unstable type ii clavicle fractures with distal. The acumed clavicle plating system and the acumed dualtrak clavicle screw system provide comprehensive solutions to treat a wide variety of clavicle fracture patterns.
The aos clavicle plate system is designed with the fundamental idea of creating advanced orthopaedic devices that will enhance not only the surgical technique for the clavicle but the corrective healing of the patient. Geissler, md, the clavicle plating system offers a variety of lowprofile and narrowprofile plating solutions. However, not all patients with a fracture located in the lateral twofifths of the clavicular shaft had anatomic fit of the plate. The acumed clavicle plating system is intended to provide fixation for fractures, malunions, and nonunions of the clavicle. A superior approach to his clavicle using rightsided acumed locking clavicle plate was applied. Two plates were implanted to replace the broken plate one superiorly and one anteriorly, and a bone graft was required. Complete clavicle system for wide range of fractures. Carroll professor of surgery of the hand chief, orthopaedichand and trauma service. With the locking clavicle plates, acumed has designed a comprehensive solution for repairing fractures located from the middle third to the distal third of the. The stainless steel plates are low profile and precontoured with locking and nonlocking screw options in each plate.
Pdf evaluation of prominence of straight plates and precontoured. A recent study evaluated construct failure after an open reduction and plate fixation and reported a construct failure rate of 6. The acusinch repair system is intended to be used in conjunction with the clavicle plating. Acumed locking superior distal clavicle plates youtube. The purpose of this study was to examine the complication pro. An osteotomy was performed on 7 pairs of human clavicles and were randomly plated with either a synthes 3. The system offers an array of low and narrowprofile plate solutions, precontoured to match the natural sshape of the clavicle. When the plate was positioned adequately, it was initially secured with a single 3. Elbow plating system brochure and surgical technique. Low profile plate design to minimize plate prominence. Reposition and fixation of unstable distal clavicle fractures with a low profile locking plate acumed, hempshire, uk in conjunction with a buttonsuture augmentation cerclage dogbone.
In line with our goal to bring to the market products that evolve and improve patient outcomes, acumed introduces three additional plate designs to the system. Locking straight plate, locking distal clavicle plates and locking anterior clavicle plates. The clavicle plating system offers low and narrowprofile plate solutions that are. Variax clavicle locking plating system operative technique. The plate is then secured using locking or nonlocking screws. Multiple plate options are available to fit a wide. Elbow plating system acumed is a global leader of innovative orthopaedic and medical solutions. A read is counted each time someone views a publication summary such as the title, abstract, and list of authors, clicks on a figure, or views or downloads the fulltext. Superior distal clavicle plate 19 acusinch repair system surgical technique 25 ordering information 33 clavicle plating diagrams 39 acumed is a global leader of innovative orthopaedic and medical solutions. Precontoured to match the natural sshape of the clavicle, this titanium plate offers increased strength, with a rounded profile and a lowprofile screw plate interface. Clavicle plating system is indicated for fixation of fractures, osteotomies and nonunions of the clavicle including osteopenic bone.
Plate length ref mm holes 628306 75 6 628307 86 7 628308 97 8 628310 118 10 anterior midshaft plates plate length ref mm holes 628406 59 6 628407 72 7 628408 83 8 anterior lateral plates all nonsterile products may be ordered sterile by placing an s at the end of the ref number. Note that, contrary to the acumed plates which are only curved in the axial plane, the depuysynthes plates are. This design not only reduces or time spent in contouring a plate but also minimizes softtissue irritation for the patient. While often treated conservatively, a portion of these fractures can benefit from a low profile locking plate that minimizes soft tissue irritation and improves patient function while.
The acumed locking clavicle plate is designed to provide excellent fixation for acute fractures, malunions, and nonunions of the clavicle. Mechanical failure of plate breakage after open reduction and plate. The acumed congruent plate is precontoured, low profile and made from titanium alloy. After plating, specimens were tested on an enduratec material testing apparatus for axial. The system is comprised of low profile anatomic plates that are designed for optimal fit, with features that assist the surgeon to. Plates utilize smartlock technology which permits polyaxial screw placement. Anatomic plate contour assists in restoring the original geometry of the.
The broken plate was removed from the patient on b6, 2010. Acumed clavicle plating system surgical technique doc. Acumed in house analysis showed that when subjected to equal force,a 3. Evaluation of prominence of straight plates and precontoured. It comes in right and left sides and different shaped curves.
A study evaluating the clinical applicability of the acumed locking clavicle plate reported that this plate is adequately shaped for the fixation of fractures in the medial threefifths of the clavicular shaft. Plating the superior aspect of the clavicle has been found to be biomechanically the most stable3. The best sleeping position for back pain, neck pain, and sciatica tips from a physical therapist duration. Distal clavicle plates utilize kwire and suture holes to verify plate and screw placement allowing the surgeon to address the most lateral fracture. Divergent locking screws can also be used laterally. This achievement affords surgeons the opportunity to choose the most appropriate option for the patient, could help reduce surgery time spent contouring a plate and may aid in minimizing soft tissue irritation for the patient. Treatment of acute clavicle fractures with an anatomical. Our objective at acumed is to provide a comprehensiv.
The fracture is held in reduction while the plate is positioned on the clavicle and temporarily fixated with the use of a bbtak pin. An acumed clavicle plate was implanted approximately 6 months ago for a nonunion. Surgical technique acumed is a global leader of innovative orthopaedic and medical solutions. Aug 21, 20 the clavicle plating system offer low and narrowprofile plate solutions precontoured to match the natural sshape of the clavicle. Pdf hardware prominence after plate fixation for clavicle fracture is a common complication. Clavicle plating system by treating coracoclavicular cc ligament injuries associated with clavicle fractures. We are dedicated to developing products, service methods, and approaches that improve patient care. Following plate removal, the mean number of days returning to work was 14 190 days and to sports was 26 1150 days. Acusinch repair system the acumed clavicle plating system is designed to treat simple and complex fractures, malunions, and nonunions. Comments about the acumed locking anterior clavicle plates independent. Locking clavicle plate brochure and surgical technique.
The clavicle plate and screw system is a comprehensive set of plates, screws, and instruments designed to treat midshaft and distal clavicle fractures. We are dedicated to developing products, service methods, and approaches that. The clavicle is an elongated, sshaped bone that rests horizontally at the sternum across the upper part of the ribcage, and the acromial end of the scapula this bone is an important part of the skeletal system since it plays an essential role in everyday functional movement, serving as the connection between the axial skeleton and the pectoral girdle. The plate may be utilized as a template to help facilitate reduction of the body of the scapula to the spine. The acumed hand plating system is intended for the managemnent of fractures, fusions, and osteotomies of the distal, mdl. Lockingclavicle platesystem university of washington. Nov 01, 2016 the best sleeping position for back pain, neck pain, and sciatica tips from a physical therapist duration.
Lockingclavicle platesystem since 1988 acumed has been. The variax 2 clavicle plating systems provides surgeons with a comprehensive range of anatomic plating options that work with a common instrument and screw platform. Displaced fractures of the clavicle generally do well with nonoperative treatment nonunion rate plate should fit along the base of the spine and down the medial border of the scapula. The clavicle hook plate provides a single solution for fixation of both lateral clavicle fractures and acromioclavicular joint injuries. Since its introduction, surgeons have utilized the acumed locking clavicle plate system to solve many complex injuries of the midshaft and distal clavicle.
Since its introduction as the orthopaedic industrys first precontoured resource for clavicle fixation, surgeons have utilized the versatility of the acumed clavicle plating system to treat simple and complex fractures, malunions, and nonunions. A choice of a midshaft or lateral plate is determined by the site of the fracture. The acumed clavicle plating system provides surgeons with the ability to address acute fractures, malunions, and nonunions of the clavicle with 33 different clavicle specific plating options. Clavicle core plating system surgical technique aked.