What kind of wall switch is needed for a natural gas. You turn the control knob to the pilot position, push the knob in, light the pilot with a match, then hold the knob down for 30 seconds or so until the pilot stays lit by itself. Open valve by pivoting handle to be parallel to gas line. Convertible ventless natural gas fireplace in cherry with up to 27,500 btus, this stateoftheart vent with up to 27,500 btus, this stateoftheart vent free technology does not require a flue or chimney. Real fyre spk26 safety pilot kit for natural gas logs this is a real fyre manual safety pilot kit to be used with certain real fyre gas log burners. The steps to light the pilot on a gas fireplace may vary some between manufacturers, but they all have a few things in common. Using your fireplace page 8 page 9 page 10 for your safety read before. With up to 27,500 btus, this stateoftheart vent with up to 27,500 btus, this stateoftheart vent free technology does not require a flue or chimney. You can also register your product and keep up to date on service, maintenance and improvements that may enhance your product. The intrigue 42 gas fireplace allows for the nicest customization in design in the industry.
Any propane will be in a large tank outside that can be. Be sure to have a long lighter before starting and youll be able to enjoy your cozy fire on a chilly night. The process for lighting a ventfree gas log fireplace involves holding the control valve open manually until the thermocouple is transferring enough of a charge to pull the control valve magnet into the open position. If you smell gas shut off gas supply do not try to light any appliance do not touch any electrical switch. I finished the install last night and turned it on. Sep 28, 2010 how to fix a gas fireplace pilot light that does not stay lit troubleshooting and repairing duration.
How to turn off your fireplaces pilot light safely quora. The valve itself could be defective and if that is the case, replacement of the valve is the only option. Its probably just a matter of finding a switch with a low enough on resistance. Set the dial to pilot, held it down for a few seconds while pushing the ignitor button several times.
Intrigue 42 gas fireplace ambiance fireplaces and grills. Took fireplace cover off, when i depress the pilot control valve, i dont smell any gas or hear any air coming through. The rating plate is found in different places, depending on the unit. This is in the basement, right below where the fireplace is on the main floor. Instead, gas fireplaces have a pilot light that is usually lit when the fireplace is initially installed. If your heaters insect guard becomes too obstructed, it can block the flow of air and smother your flame. To avoid accidentally turning off the pilot light when turning off the burner, there is generally a mechanical block to pr. The fireplace has an electric solonoid valve that turns the gas on and off this is the same kind of valve that is used in forced air furnaces. I turned off the gas valve, turned it on to pilot pushed it in, and hit the light button. How to light the pilot on your gas log set general instructions. The kingsman zeroclearance ventfree gas fireplace is a 33 inch unit for larger spaces. If the burner doesnt light within a few seconds, start the process over again. Do you have a gas fireplace or gas logs controlled by a wall mounted onoff switch maybe you have a full function remote that controls fans, lights, flame height.
Pleasant hearth vent free fireplace systems are the ideal choice to bring style and warmth to your home. Ensure the gas is turned on to allow gas to the fireplace. If you keep trying for a longer period of time, gas can build up and cause an explosion. The gas supply to the pilot light will be cut off and the flame will go out. Unvented ventfree gas fireplace owners operation and installation manual shown with optional cabinet mantel, hearth base, and trim accessories. A gas fireplace remote control will allow you to easily start your gas fireplace with the. Installing firestones in natural gas and propane fireplaces.
I tired lighting manually with a lighter and nothing. Most gas patio heaters have a bug screen to keep away insects that are attracted to the flame. Check to make sure they are off by pushing the control knobs in and turning them clockwise until they stop. Different gas fireplace inserts present different challenges.
How to light fireplace pilot stepbystep instructions. Troubleshooting an intermittent pilot ignition system. A generic low voltage switch from a electronics store, or ripped out of a toy, would probably do it for example a 12v spst. When the switch was off, there was a small flame which i assume was the pilot. Mendota gas fireplaces, gas fireplace inserts and gas stoves are sold through a nationwide network of authorized mendota dealerships. Locate pilot assembly with spark ignitor located behind and below logs in the firebox typically in the bottom center. How do i light my majestic direct vent gas fireplace. Now return to your gas fireplace and turn the gas valve on. Select your model number to find the installation manual for your fireplace. Now turn the fireplace control knob on the access panel so that its marking aligns with the pilot setting. The thermopile in your fireplace puts out millivolts, nothing near the 120v the light switch was designed for. The pilot light flame must hit the thermocouple correctly, or the voltage the thermocouple generates may not be enough to operate the main gas valve, while it is enough to keep the pilot light lit. Max 23,500 btu input 21,500 propane 74% efficiency, will heat 1,2001,400 square. Do not use a natural gas set for a propane or a propane set for natural gas.
Similar to the pilot line, the pilot valve light itself can become clogged. Heres how to start that fire and get your toes toasty. Hargrove gas logs installation and operation manual pdf download. Hi, we have a heatilator gas fireplace that wont light when we flip the wall switch. For remote controlled gas logs, this will put the valve in the.
Au gas insert light instructions lanai gas fireplace installation manual. If the gas main to the fireplace is on it should provide gas even if. It was working fine until i shut off the gas to the fireplace. Apr 06, 2008 the gas valve has a very small orifice that supplies the gas to the burner. Turn off the gas valve and pilot light before cleaning fireplace. Just had my lp gas log fireplace installed yesterday. From the off position, turn gas control knob counterclockwise to ign position. Gas fireplaces however do not have to be lit manually every time theyre used. Fireplace xtrordinair offers extraordinary models of premium traditional or contemporary wood or gas burning fireplaces and fireplace inserts, with dozens of beautiful designer faces and fireback combinations to personalize your fireplace.
Turn the gas control until the pilot setting lines up with the hash mark on the outer rim of the control. Real fyre spk26 safety pilot kit for natural gas logs. This heater is equipped with a pilot light safety sys. Constant burning can weaken metal housing and cause it to crumble and block gas. If you dont have this, try searching for your fireplaces manufacturer and. Gas fireplace updates the fireplace guys minneapolis. How to repair a gas fireplace if it wont turn on angie.
Remove the screen and clean it either by blowing on it or with a quick wash and thorough drying. Intrigue 36 gas fireplace by ambiance fireplaces and grills. At the fireplace guys, our team of professionals remains current on the latest trends in fireplace design and function. Feb 14, 2014 this appliance has a pilot that must be lit manually. It is a standing pilot light which stays lit indefinitely. If something blocks this orifice it will not allow the gas to flow. With control knob pushed in, push in and release the.
Series operates manually and also features a variable speed control. Release the gas control dial and turn it to the on position, with the pilot light remaining lit. Now comes the part that makes the gas fireplace so convenient, lighting the flame that. How to fix a gas fireplace pilot light that does not stay lit troubleshooting and repairing duration. Kingsman zero clearance vent free gas fireplace 33 inch. Follow the gas suppliers instructions if you cannot reach your gas supplier, call the fire department 4. It is supposed to have a pilot that lights automatically.
To determine the largest set that will fit in a fireplace, the width at the center of the fireplace is the critical dimension. The manual safety pilot is the most basic safety pilot. Lighting, operation and care of this fireplace can be easily performed. Have venting system inspected annually by a qualified service person. Gas fireplaces can be liquid propane gas or natural gas. If the pilot doesnt light, wait 10 seconds and push again. So we went to turn on our gas fireplace christmas day. Quality fireplaces that stand the test of time, we will help you find the perfect fireplace, insert or stove for your home. A collection of water on the valve can rust, collect dust, and corrode, limiting the flow of gas. My fireplace has a wall switch that would turn on the gas. The pilot light would stay lit just fine, but when id hit the wall switch, id wait 56 seconds and the fireplace would light with a dramatic whoooomph.
Steps outlined for getting gas fireplace pilot light going. The installing dealer is responsible for providing service and. View and download hargrove gas logs installation and operation manual online. Read this manual before installing or operating this appliance. How can i start my gas fireplace if the power is out. Put the match in the match stick holder and strike the match to light it. If it is blown out by heavy winds it does have to be relit. Apr 26, 2018 turn the gas control until the pilot setting lines up with the hash mark on the outer rim of the control. Jul 17, 2017 hold the flame of a fireplace lighter or match at the tip of the pilot light tube to ignite the flame, continuing to hold down the control dial for 90 seconds. The intrigue 36 gas fireplace comes standard with a matte black interior finish, the ecotel programmable thermostatic remote, a 150cfm convection fan and accent lights. Choice of natural or lp gas ceramic fiber logs with realistic glowing embers can be placed directly on carpet or wood floors limited 5 year warranty. Do i need to reset it the other way to let gas through to light the oven.
While every one of these fireplaces embody the same attention to detail in design and construction, each. Turn it counterclockwise to let gas reach the fireplace. Worthen adds the newer systems with electric igniters are more sensitive, and require the consumer to figure out if the issue lies in the electronic ignition or pilot. Download 34 gas zircon installation instructions pdf gas direct vent malm 34 zircon cone fireplace features. If needed, have venting system cleaned or repaired. Paul metro area gas fireplace company today to get started on updating your fireplace. So the pilot light on your gas fireplace is out and you cant get it going again. If you are running the heater for the first time, it may be necessary to press in the control knob for 30 seconds or longer to allow air to bleed out of the gas piping. The switch simply connects a circuit that opens the valve. Nothing turns a cool night cozy like a warm glow from a hearth, and propane or natural gas fireplaces avoid the hassle of building and maintaining a wood fire. Page 3 fireplace sizes each gas log set requires a minimum 16inch front opening height and minimum 16inch depth. Follow the instructions in your manual under what to do if you smell gas.
Top efficiencies, beautiful fires and decorative door options. I know to turn the valve on, rotate the wheel to pilot. From off position, push in gas control knob slightly and turn counterclockwise to the ign position. You can customize the look of your intrigue 36 to fit your home. Try adjusting the pilot light so that it more directly hits the thermocouple, check for clogged holes in the gas supply for the pilot as the. This vent free fireplace system functions on natural gas only.
Wireless remote control this fireplace features an infrared wireless remote. Installer must instruct the homeowner how to operate the burner. Before lighting, smell around the appliance area for gas. If the pilot light is extinguished when the control dial is released, repeat steps 5 and 6. Propane gas fireplace pilot wont light home improvement. Soon we will explain the process of the thermocouple to help understand the safety features in your vent free gas fireplace. If you choose to equip a zvfb33p millivolt burner specifically, then it can be matched with a full line of remotes or wall switches and is certified for use in the usa and canada. Installation instructions and owners manual fines gas. Other gas fireplace repairs include loose connections, defective valves or bad modules in electric ignition units, according to experts. In order to manually light a gas fireplace, make sure the damper is open and slowly turn on the gas when its moving over the lighter or matches. Do not use any solid fuels wood, coal, paper, cardboard, etc.
Put the match in the match stick holder and strike the match to. Quick video on how to light a gas fireplace in your house. On the side firebox column or under the ash lip in the control compartment. These professionals have both the knowledge and experience to help you select the correct size fireplace for your home and provide expert installation and service.
When lighting the pilot, follow these instructions exactly. This can be done by flipping a wallmounted switch, if one has been installed for your gas fireplace, or by manually turning the valve on inside the access panel of your fireplace. Page 1 page 2 page 3 safety and warning information page 4 consumer reference information page 5 table of contents page 6 section 1. Make sure all the burner control knobs are turned off. Locate gas supply valve typically behind louvers, below glass opening may be red or blue. Recently, i noticed that it was taking a long time for my gas fireplace to light. How to light a pilot light on a trane furnace hunker. For manually operated gas logs such as the one pictured to the right, this will turn the logs on.